Thermador Refrigerator Error Codes: E01 to E34, Ice Maker Codes and DEMO Mode

A Thermador built-in refrigerator will tell you what is wrong, but only in a language of short E-codes, a few plain-English words on the display, and a red light on the ice maker. Most people meet the problem first as a symptom: the display says DOOR OPEN with nobody in the kitchen, the ice bin stays empty, or the whole refrigerator shows DEMO and stops cooling. This guide explains what each message means and what is usually behind it, so that you can write down the right code before you call us.

A note on where this comes from. The factory documents in our Thermador file are repair documents from BSH, the company behind Thermador and Bosch built-in refrigerators. The code table below is from the service tech sheet for the E2006 BM control (BSH document 53510000037584, revision A, November 2012), backed by the ice maker error list for the same refrigerators and by the repair instruction for the 36-inch bottom-freezer T36IT70NNP, a Thermador model number. BSH writes these documents for the platform rather than for one badge, so treat the table as the code list for this built-in family, not as a promise about every Thermador refrigerator ever made. Other generations use different displays; if your code is not here, send us the nameplate model number and the code, and our technician will read the fault memory directly.

How these refrigerators show a fault

There are three places to look. The first is the main display, which shows an E-code or a word such as LOWPOWER. The second is the ALARM symbol, which flashes along with a beep when the freezer has stayed warm: the documents set that trigger at 21 degrees F for 30 minutes, with no alarm during defrost or for the two hours after it. Pressing ALARM OFF silences the beep and shows the warmest temperature the freezer reached for about 10 seconds. Write that number down. It tells us how warm the food got and how long the problem has been running.

The third place is the ice maker, which has its own electronics and reports its own E-codes. One detail from the ice maker list is worth knowing: on some communication faults the code is hidden until you press the ALARM OFF button, so a refrigerator with a blank-looking display may still be holding a code.

The documents also describe a technician-only service test mode that runs each load, sensor and switch one at a time. It is not a customer menu, and we do not publish the key sequence.

The E-code table

The center column follows the wording of the BSH documents, and the right-hand column says how we approach each one.

Code What the documents say What we check, and when to call
E01 Refrigerator compartment sensor: break, short circuit or no contact The sensor and its connection, then the control. Call the same week; the refrigerator side loses its temperature reading.
E02 Freezer compartment sensor: break, short circuit or no contact Same approach on the freezer side. Call promptly if food is softening.
E06 Refrigerator evaporator sensor, shown after the auto-diagnostic test This sensor supports defrost. Call if you see frost on the back wall or weak airflow.
E07 Freezer evaporator sensor, shown after the auto-diagnostic test Same role for the freezer. Frost build-up with a blank display points here.
E15 Ambient (room) sensor: break, short circuit or no contact The room sensor and its wiring. Not an emergency, but the control is working with bad information.
E10 Power module memory incompatible with the software or damaged Control electronics. Call the same day.
E11 Display module memory incompatible with the software or damaged Control electronics. Call the same day.
E20 Communication error between the power module and the display module The link between the two modules, then the modules. Call the same day.
E30 Ice maker tray motor or ice level detection switch error Whether the tray or arm is blocked, then the connector and the ice maker. Call if no ice.
E31 Ice maker tray or water tank temperature sensor defect The ice maker sensors, then the ice and water electronics.
E32 Communication error between the ice and water system and the main control The data cable and sockets, then the ice maker control. May need ALARM OFF to appear.
E33 Ice chute flap motor or switch error, dispenser models only The chute flap and its connection. Call if the dispenser will not release ice.
E34 Hopper flap switch error, dispenser models only The hopper flap lever and the crusher mechanism.

The tech sheet also treats E32 and E20 showing together as a separate case, one more reason we read every code before ordering a part.

Messages that are words, not codes

Message What the documents say What it means for you
LOWPOWER Mains below 85 volts for US appliances The refrigerator stops working until voltage recovers. Call us if it repeats; the outlet or circuit needs checking too.
HIGH VOLT Mains above the allowed limit The supply is above the control’s limit. Call us; the outlet and circuit need checking.
DOOR OPEN A door has not closed properly during a set time Close the door fully and check that nothing holds it. If it persists with doors closed, we check the door switches.
FILTRCHG Water filter used longer than six months The filter is due. Not a fault, and not every model has a filter.

The door-open delay is not the same in every document: one repair instruction says 30 seconds, another 60 seconds, and the side-by-side version 180 seconds. That is a good example of why the model number matters.

The DEMO message and the condenser fan

This is the Thermador-family detail most owners never hear about. The tech sheet says that if the control notices three condenser fan failures, the unit switches itself into Demo mode as a protection. In Demo mode the display looks normal, but the only loads that run are the light and the compartment fan after the door closes. Nothing cools. The sheet also notes that Demo mode is not cleared by a power interruption, so flipping the breaker will not end it.

If your built-in has gone quiet and warm while the display still looks fine, tell us. Do not try key combinations from the internet to exit Demo mode; exiting it without fixing the fan only lets the control run into the same fault again, and the food in the freezer is the price of the experiment.

The ones that mean call today

  • E10, E11 or E20. These point at the control electronics themselves, not a sensor.
  • E01 or E02 with warm food. The control has lost its temperature reading.
  • DEMO on a refrigerator that is not cooling. This can be the three-strike protection described above.
  • A freezer ALARM that keeps returning. The documents set the trigger at 21 degrees F.

Ice maker codes and the no-ice complaint

Ice trouble is the most common reason people look up these codes. The ice maker documents give a troubleshooting plan, and its first instruction is a good one for owners too: do not turn off the appliance or the ice maker before you have noted the error code, and note it on the repair paperwork. From there, the plan asks a series of questions that you can answer without opening anything:

  • Is ICE showing on the display, with Vacation, Sabbath and Rest modes off?
  • Is the freezer door fully closed, with nothing blocking it?
  • Is the lever arm under the ice maker free of food packages or ice build-up?
  • Is the water tap open and the filter cartridge seated correctly?
  • Is the water pressure between 2 and 8 bar, roughly 29 to 116 psi? Below 2 bar the plan says to advise the customer; above 8 bar it calls for a pressure regulator.

If those are fine and the ice maker still will not start its self test, the plan moves to the water valve, the inlet heater and the electronics, which is technician work. Ice building up around the tray and lever arm can also mean a water valve is leaking, a fault that should not wait. Our guide to an ice maker that is not making ice covers the symptom across brands.

Why we do not guess parts

An E31 says an ice maker temperature sensor is out of range; it does not say whether the sensor, the wiring or the electronics failed. The ice maker list itself checks in order before it says to replace a part, and we work the same way: read every code, test the suspect component, quote the actual repair, and credit the diagnostic fee toward it. On a built-in, sensors, fans, ice makers, valves and boards are worth repairing; replacement is a conversation only for an older unit with a sealed-system failure.

If your refrigerator is the Bosch version of the same platform, our Bosch refrigerator error codes guide covers the flashing ice maker codes. For another high-end built-in brand, see our Sub-Zero refrigerator error codes.

Thermador refrigerator repair across the Denver Metro

FiXiFY repairs Thermador built-in refrigerators across Denver, Aurora, Lakewood, Westminster and the surrounding metro, with genuine OEM parts. With Thanksgiving close, book early and keep the code you wrote down. Start with our Thermador repair page, the built-in refrigerator repair page, or refrigerator repair in general.

BOOK ONLINECALL (303) 214-1240

FAQ

What does E20 mean on a Thermador refrigerator?

In the BSH tech sheet E20 is a communication error between the power module and the display module. It is a control electronics problem, so book a technician rather than waiting for it to clear.

Why does my Thermador refrigerator say DEMO and not cool?

The tech sheet says the control switches to Demo mode after noticing three condenser fan failures, and Demo mode survives a power interruption. In that mode only the light and the compartment fan run, so a technician needs to find and fix the fan fault.

What do E30 to E34 mean on a Thermador built-in?

They are ice maker codes: E30 tray motor or ice level switch, E31 ice maker or water tank sensor, E32 communication with the ice and water system, and E33 and E34 the chute and hopper flaps on dispenser models. Some communication faults only show after you press ALARM OFF.

What water pressure does a Thermador ice maker need?

The ice maker troubleshooting plan asks for between 2 and 8 bar, roughly 29 to 116 psi. Under 2 bar the customer is advised, and over 8 bar the plan calls for a pressure regulator.

FiXiFY Appliance Repair — 7030 E 46th Ave Dr, Unit A, Denver, CO 80216 · (303) 214-1240 · support@fixifycolorado.com